| MODEL(380-400-415V 3ph version) |
PDSP33010 |
PDSP33015 |
PDSP33020 |
PDSP33030 |
PDSP33040 |
PDSP33060 |
PDSP33080 |
PDSP330100 |
| Output Power (kVA) |
10 |
15 |
20 |
30 |
40 |
60 |
80 |
100 |
| Nominal Active Power (kW) |
8 |
12 |
16 |
24 |
32 |
48 |
64 |
80 |
| MODEL(200-208-220V 3ph version) |
PDSP-U33005 |
PDSP-U33007 |
PDSP-U33010 |
PDSP-U33015 |
PDSP-U33020 |
PDSP-U33030 |
PDSP-U33040 |
PDSP-U33050 |
| Output Power (kVA) |
5 |
7.5 |
10 |
15 |
20 |
30 |
40 |
50 |
| Nominal Active Power (kW) |
4 |
6 |
8 |
12 |
16 |
24 |
32 |
40 |
| INPUT |
|
| Number of phases |
3Ph + N + PE |
| Nominal Voltage (Ph-Ph) |
200V/208V/220V (PDSP-U) or 380V/400V/415V (PDSP) |
| Voltage Range (100% load) (Ph-N) |
(-15)%(+27)% |
| Voltage Range (64% load) (Ph-N) |
(-45)%(+27)% |
| Voltage Range (42% load) (Ph-N) |
(-64)%(+27)% |
| Nominal Frequency (Hz) |
50 or 60 |
| Frequency range for online operation |
±10% |
| Input Current THD |
≤4%(*) |
| Input Power Factor |
0,99 |
| OUTPUT |
|
Power Factor |
0.8 |
| Number of phases |
3Ph+N+PE(PDSP&PDSP-U) |
3Ph+N+PE(PDSP&PDSP-U) |
Voltage (3ph_Phase to Phase) |
200V/208V/220V (PDSP-U) or 380V/400V/415V (PDSP) |
200V/208V/220V (PDSP-U) or 380V/400V/415V (PDSP) |
| Static Voltage Regulation at %100 Linear Load (online&battery mode) |
<1% |
| Voltage THD at rated linear load |
<3% |
| Crest Factor |
3 : 1 |
| Frequency (Hz) |
50 or 60 |
| Free Running Frequency (Hz) |
± 0.01% |
| Overload |
125% for 10 minutes , 150% for 1 minute |
| Efficiency |
up to 95% (**) |
| BATTERY |
|
| Type |
Maintenance-free lead acid batteries |
Quantity (pcs) PDSP version |
62 (2*31) |
Quantity (pcs) PDSP-U version |
34 (2*17) |
| Battery Protection |
Deep Discharge Protection with Auto Cut off |
| Battery Test |
Standard (Automatic and Manual) |
| DISPLAY |
|
| LED Display |
Line, Bypass, Battery, Inverter, Load, Fault Indications |
| LCD Display |
Load%, Input&Output Frequency, Voltage&Current, Bypass voltage, Battery Voltage & current, Temperature, Alarms |
| STATIC BYPASS |
|
| Number of phases |
3PH+N+PE |
| Voltage Range for bypass operation |
±10% |
| Frequency Range for bypass operation (Hz) |
±6% (Configurable) |
| COMMUNICATION |
|
| Interface (Communication Ports) |
RS232&RS422 |
| Dry Contact Signals |
AC failure, Battery under voltage, bypass operation, output failure |
| Others |
EPO, Generator interface |
| ENVIRONMENT |
|
| Storage Temperature Range (°C ) |
-25 to +55 ( 15 to 40 recomended for longer battery life time ) |
| Operating Temperature Range (°C ) |
0 to 40 ( 20 to 25 recomended for longer battery life time ) |
| Relative Humidity Range |
0-95% (non-condensing) |
| Maximum Altitude without derating (m) |
1000 |
| Protection Level |
IP 20 |
PYSICAL SPECIFICATIONS |
| Dimensions wxdxh (cm) |
40x78x107 |
52x90x130 |
52x95x130 |
64x98x140 |
| Weight (kg) |
102 |
110 |
110 |
110 |
240 |
242 |
260 |
295 |
| Product Certification |
CE |
| STANDARDS |
Standards |
EN 62040-1-1 (safety), EN 62040-2 (EMC), EN 62040-3 (VFI-SS-111) |
| (*) for source having THDv <2 % @ nominal load |
| (**) varies depending on ups power |
| (!) 50/60 Hz Frequency Converter Versions are available |